ED100% BDA Solenoid Coil BDA08012CS BDV08012CY BDA08024CS BDV08024CY
When people use the solenoid valve coil, they don't pay attention to the problem, but they should pay attention to the problem. Otherwise, it will not only be used badly, but will affect people's health. It will also cause damage to their running equipment. . So how to use the solenoid valve coil is better?
1. Because the solenoid valve coils are not of the same type, and the lengths of the different models are different, then people need to use them according to their own needs. In this way, it can play more roles in use. Even if there is a problem, it can solve the problem in time to avoid the occurrence of the fault. Therefore, it is better to control the length of the solenoid valve coil. It will be much better to do according to your own needs.
2. Pay attention to the voltage problem in the use of the solenoid valve coil. Because you want to use it well, you should pay more attention to the voltage range. Because the voltage is too high, it will burn out the product, which will cause unnecessary waste. Therefore, when people use it, they should not be too lazy. Control the voltage problem.
For the solenoid valve coil to use, in order to make it work, then the above two points are to pay more attention, so that the product can create value for people in use.
What problems occur when the solenoid valve coil is in use?
Everyone knows that solenoid valves play an important role in industrial applications, and they have a long running time, and sometimes there are some problems that make the equipment not function properly. Most of this problem is caused by improper use of the solenoid valve coil.
The solenoid valve coil may not be very secure at the time of installation. During the operation of the device, the coil is in a strong operation, so that the coil will fall, the solenoid valve will not operate normally, or some may fall, and some may not. It may cause the device to work for a while and not work properly, both of which will delay the work. At this time, the operation is relatively simple, and the coil can be firmly fixed on the solenoid valve. There is also a case where the solenoid valve coil may be burnt out due to excessive voltage, and the device may not operate normally.
Therefore, when using the solenoid valve later, be sure to check the position of the solenoid valve coil and do the correct operation of the solenoid valve coil. This will ensure that the solenoid valve will not cause problems.
Dimension of BB13239027 Solenoid Valve Coil :
Technical Data:
Solenoid Coil Production Line:
Attention:
1. This air suspension compressor pump solenoid coil is made of high quality components.
2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.
Steps and methods for properly installing a solenoid valve coil:
1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.
2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.
3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.
4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.
5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.
6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.
7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.
Product Features:
1. Using high quality wire which has UL approved; 2. Using high quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof coils and so on.
7. If you have special requirement, pls feel free to contact us.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
담당자: Mr. Brandon Bao
전화 번호: 86-13454729544
팩스: 86-574-83879820
EVR 3 NC 032F8107 1/4'' Danfoss 유형 냉동 솔레노이드 밸브 220VAC
1028/3 Castel Type 3/8'' 냉동 솔레노이드 밸브 HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss 유형 암모니아 솔레노이드 밸브 042H1128 042H1132
ASCO 맥박 벨브 SCG353A043 SCG353A044를 위한 C113443 C113444 격막